OMICRON-LAB B-LFT100

Low Frequency Injection Transformer

OMICRON-LAB B-LFT100 Low Frequency Injection Transformer

B-LFT 100 is especially designed to inject low frequency signals into slow control loops such as PFC regulators. To ensure maximum signal/noise in your measurements, the B-LFT 100 is capable of injecting a 1 Hz signal at the full 2 Vrms output power of Bode 100 without saturating. For your safety, B-LFT 100 features a safely isolated (600V CAT II) output.

Key features

  • Optimized for low frequency injection
  • Extremely low cutoff frequency
  • Low insertion loss
  • 600V CAT II isolated output

Some technical data

  • Usable frequency range: < 100 kHz
  • -3 dB frequency: typ. << 1 Hz - 30 kHz
  • Insertion loss: typ. < 1 dB
  • Turns ratio: 1:1